SEMI G43 - Test Method for Junction-to-Case Thermal Resistance Measurements of Molded Plastic Packages -
Abstract
The
purpose of this test is to determine the thermal resistance of molded plastic
packages using thermal test chips. This Test Method deals only with
junction-to-case measurements of thermal resistance and limits itself to fluid
bath testing environments. For this test, conduction through the leads is
minimized, thus providing information on the ability of the plastic package
material to dissipate heat.
This
Test Method should only be used for comparing the thermal characteristics of
plastic packages in the same fluid bath system due to the thermophysical
properties of the heat transfer fluids used and the effects of the variable
nature of the fluid-stirring and package-mounting procedures.
Referenced SEMI Standards
SEMI G32 — Guideline for Unencapsulated Thermal Test Chip